You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

2.4 KiB

icon date category tag headerDepth
edit 2022-12-26
nodejs
modbus
5

nodejs 运行modbus

npm 安装 modbus-serial

npm install -g modbus-serial

modbus 客户端

// create an empty modbus client
var ModbusRTU = require("modbus-serial");
var client = new ModbusRTU();

// open connection to a tcp line
client.connectTCP("127.0.0.1", { port: 8502 });
client.setID(1);

// read the values of 10 registers starting at address 0
// on device number 1. and log the values to the console.
setInterval(function() {
    client.readHoldingRegisters(0, 10, function(err, data) {
		if(data){
			 console.log(data.data);
		}
    });
}, 1000);

modbus 服务端

// create an empty modbus client
var ModbusRTU = require("modbus-serial");
var vector = {
    getInputRegister: function(addr, unitID) {
        // Synchronous handling
        return addr;
    },
    getHoldingRegister: function(addr, unitID, callback) {
        // Asynchronous handling (with callback)
        setTimeout(function() {
            // callback = function(err, value)
            callback(null, addr + 7000);
        }, 10);
    },
    getCoil: function(addr, unitID) {
        // Asynchronous handling (with Promises, async/await supported)
        return new Promise(function(resolve) {
            setTimeout(function() {
                resolve((addr % 2) === 0);
            }, 10);
        });
    },
    setRegister: function(addr, value, unitID) {
        // Asynchronous handling supported also here
        console.log("set register", addr, value, unitID);
        return;
    },
    setCoil: function(addr, value, unitID) {
        // Asynchronous handling supported also here
        console.log("set coil", addr, value, unitID);
        return;
    },
    readDeviceIdentification: function(addr) {
        return {
            0x00: "MyVendorName",
            0x01: "MyProductCode",
            0x02: "MyMajorMinorRevision",
            0x05: "MyModelName",
            0x97: "MyExtendedObject1",
            0xAB: "MyExtendedObject2"
        };
    }
};

// set the server to answer for modbus requests
console.log("ModbusTCP listening on modbus://0.0.0.0:8502");
var serverTCP = new ModbusRTU.ServerTCP(vector, { host: "0.0.0.0", port: 8502, debug: true, unitID: 1 });

serverTCP.on("socketError", function(err){
    // Handle socket error if needed, can be ignored
    console.error(err);
});